Commercial battery energy storage system

ENERSTO 11264 - 112 kWh

ENERSTO 112 combines lithium iron phosphate batteries, three-phase power conversion and intelligent COMEXIO energy management in one modular system. It is designed for offices, retail, hospitality and mixed-use properties that want to lower demand peaks, use more solar energy and protect critical loads.

ENERSTO 11264 - 112 kWh
ENERSTO 112 battery energy storage system

Technical specifications

Key system data.

Values shown here are taken from the current ENERSTO 112-224 data sheet. Final system design is confirmed from the site load profile, grid connection and required operating strategy.

Usable capacity range64 - 112 kWh
Peak inverter power33 kW
Nominal inverter power18 kW
Battery charging powerapprox. 15 kW
Battery modules4 - 7
Output voltage3 x 230 V / 400 V
Recommended annual consumption20,000 - 70,000 kWh
Recommended PV power20 - 100 kWp
Operating temperature-20 °C to 40 °C
Protection classIP44
Battery technologyLithium iron phosphate
Cycle life8,000+ cycles
Emergency power reserve10% - 90% adjustable
Dimensions (H x W x D)approx. 2356 x 1206 x 962 mm

System value

Designed around measurable site outcomes.

01

Reduce demand peaks

The energy management system discharges the battery when site demand approaches a defined grid limit, reducing peak power and improving the use of the existing connection.

02

Increase solar self-consumption

Surplus photovoltaic energy is stored for later use instead of being exported, helping the site purchase less electricity from the grid.

03

Protect critical operations

An adjustable emergency power reserve keeps battery capacity available for selected loads when backup operation is part of the project design.

Applications

Where ENERSTO 112 creates value.

  • Offices and business parks
  • Retail and supermarkets
  • Hotels and hospitality
  • Mixed-use properties
  • Commercial EV charging

Frequently asked questions

Plan with the right information.

What size of site is ENERSTO 112 designed for?

The recommended range is approximately 20,000 to 70,000 kWh annual electricity consumption and 20 to 100 kWp of photovoltaic capacity. Final sizing depends on the load profile and operating objective.

Can ENERSTO 112 provide emergency power?

Yes. Emergency power can be configured for selected loads, with an adjustable battery reserve of 10% to 90%. The exact backup scope is defined during project engineering.

Can the system be expanded later?

Yes. ENERSTO 112 supports four to seven 16 kWh battery modules, allowing capacity to be matched to the project and expanded within the system range.